# V-BLACK Command Protocol Manual (nRF52)
# Date: 2026-01-19 | Transport: BLE NUS
introduction:
rx_char: Commands (Write)
tx_char: Data/Responses (Notify)
mandatory_step: Send PROG_ON before any W or R command
global_commands[5]{cmd, description, response}:
PROG_ON, Enable Program Mode / Stop Alarm, PROG_MODE: ON
PROG_OFF, Exit Program Mode / Save Data, PROG_MODE: OFF
RESET, Reset alarm output and counters, INFO: Uscita allarme resettata (BT).
CALI, Toggle Diagnostic RAW Mode, --- MODALITA CALIBRAZIONE ATTIVA ---
FACTORY, Restore factory defaults, FACTORY RESET DONE
write_parameters[7]{id, name, range, default, desc}:
W1, Min Threshold, 0-2000, 1200, Impact sensitivity (100-500 high)
W2, Max Threshold, 0-4095, 4000, Upper noise filter
W3, Pulse Count, 1-50, 2, Pulses for alarm trigger
W4, Time Window, 10-1000, 40, Analysis cycle in ms
W20, Gain (Wiper), 0-255, 128, Digital pot (0:max)
W11, Min Pulse Dur, 0-1000, -, Advanced/Reserved
W12, Max Pulse Dur, 0-1000, -, Advanced/Reserved
read_commands[3]{cmd, response_format, meaning}:
R1, PARAM: W1=<val>, Read Min Threshold
R2, PARAM: W2=<val>, Read Max Threshold
R20, PARAM: W20=<val>, Read Gain (Wiper)
notifications:
heartbeat: {format: "SENSOR:<val>", interval: 500ms, ideal_rest: 2067}
alarms[3]{msg, cause}:
ALARM: TRIGGERED, Vibration threshold met
ALARM: TAMPER, Wire cut/short (0 or 4095)
INFO: Allarme resettato automaticamente, Siren timeout (5s)
errors:
- ERRORE: I comandi 'W' sono accettati solo in modalità programmazione.
- ERRORE: ID Sconosciuto
- ERRORE: Formato comando non valido